Secondary aorto-enteric fistula after aortic aneurysm repair

Duy Kien Phan , Trung Kien Nguyen1, Kim Cao Le, Dinh Long Hai Nguyen, Quoc Hung Phan
1 Khoa Phẫu thuật Mạch Máu, Bệnh viện Chợ Rẫy

Main Article Content

Abstract

Overview: Secondary Aorto-enteric fistula (sAEF) is a serious complication after open abdominal aortic aneurysm (AAA) repair, diagnosis and treatment are the sacraments for a vascular surgeons.


Objectives: Describe the patient’s characteristics and treatment results of a series of clinical cases diagnosed with Secondary Aorto-enteric Fistula after surgery to open abdominal aortic aneurysm repair.. 


Methods: A clinical case series.


Results: Report on 3 clinical cases of Secondary Aorto-enteric Fistula admitted to the hospital due to gastrointestinal bleeding, underwent surgery to completely remove the graft infection, restore the intestinal fistula, perform extra-anatomic bypass (axillary-bifemoral), the results showed one patient died early postoperatively due to multiple organ failure, two patients had stable postoperative progress and were discharged.


Conclusions: Secondary Aorto-enteric Fistula is a rare complication, diagnosis and treatment are often very difficult, early surgery to remove the graft, performing extra-anatomic bypass is an effective method, helping to reduce the mortality rate.

Article Details

References

1. Hallett JW, Jr., Marshall DM, Petterson TM, Gray DT, Bower TC, Cherry KJ, Jr., et al. Graft-related complications after abdominal aortic aneurysm repair: reassurance from a 36-year population-based experience. J Vasc Surg. 1997;25(2):277-84; discussion 85-6.
2. O'Hara PJ, Hertzer NR, Beven EG, Krajewski LP. Surgical management of infected abdominal aortic grafts: review of a 25-year experience. J Vasc Surg. 1986;3(5):725-31.
3. Brock RC. Aortic homografting; a report of six successful cases. Guys Hosp Rep. 1953;102(3):204-28.
4. Baril DT, Carroccio A, Ellozy SH, Palchik E, Sachdev U, Jacobs TS, Marin ML. Evolving strategies for the treatment of aortoenteric fistulas. J Vasc Surg. 2006;44(2):250-7.
5. Kakkos SK, Bicknell CD, Tsolakis IA, Bergqvist D, Hellenic Co-operative Group on Aortic S. Editor's Choice - Management of Secondary Aorto-enteric and Other Abdominal Arterio-enteric Fistulas: A Review and Pooled Data Analysis. Eur J Vasc Endovasc Surg. 2016;52(6):770-86.
6. Kuestner LM, Reilly LM, Jicha DL, Ehrenfeld WK, Goldstone J, Stoney RJ. Secondary aortoenteric fistula: contemporary outcome with use of extraanatomic bypass and infected graft excision. J Vasc Surg. 1995;21(2):184-95; discussion 95-6.
7. Bergqvist D, Bjorck M. Secondary arterioenteric fistulation--a systematic literature analysis. Eur J Vasc Endovasc Surg. 2009;37(1):31-42.
8. Goshtasby P, Henriksen D, Lynd C, Fielding LP. Recurrent aortoenteric fistula: case report and review. Curr Surg. 2005;62(6):638-43.
9. Hashimoto M, Goto H, Akamatsu D, Shimizu T, Tsuchida K, Kawamura K, et al. Long-Term Outcomes of Surgical Treatment with In Situ Graft Reconstruction for Secondary Aorto-Enteric Fistula. Ann Vasc Dis. 2016;9(3):173-9.
10. Batt M, Jean-Baptiste E, O'Connor S, Saint-Lebes B, Feugier P, Patra P, et al. Early and late results of contemporary management of 37 secondary aortoenteric fistulae. Eur J Vasc Endovasc Surg. 2011;41(6):748-57.
11. Hưng ĐQ, Thắng ND, Dự PG, Hiền DT. Rò động mạch chủ - đường tiêu hóa. Tạp chí Tim Mạch học Việt Nam. 2016(75):28 - 37.